Art.4312 - Installation instructions
HOW TO CONNECT ELECTRIC LOCK
The door-open” relay can operate either as dry contact or capacitive discharge mode.
In dry contact” operation mode the relay works in a traditional way, a power supply or a power source is needed to operate the
lock (12-24Vac/dc 2A max), and activation lasts according to the door opening time programmed.
Connect the external power supply + terminal to C and the terminal to GND. Connect the rst terminal of the device you want
to activate to NO and the other one to GND.
In capacitive discharge” operation mode the relays contacts, when active, supply directly the lock (12Vac/dc 2A max) for a
moment. You don’t need a power supply for the lock and the door opening time programmed do not aect the activation time.
Connect the +C terminal to C. Connect the rst terminal of the door lock to NO and the other one to GND.
* NOTE: in capacitive discharge modality (electric lock 12Vac/dc 2A max) the relay time cannot be more than 6 sec-
onds because it could overhead the device.
A possible deterioration of the mechanical performance of the electric lock, might cause the capacitive discharge” malfunctioning
in time. In case the electric lock is used in very dusty environments or in peculiar climate conditions, we suggest to use the open
door relay in dry contacts” mode.
Videx Electronics S.p.A.
Via del Lavoro 1, 63020 Monte Giberto (FM)
Phone: +39 0734 631669 - Fax +39 0734 631669
www.videx.it - info@videx.it
Autore:
Data modifica:
Data creazione:
Title:
Notes:
Titolo:
Note: Cod.File:
Foglio
/
Dopo qualsiasi cambiamento nella programmazione dei dip switch di un posto esterno o di un videocitofono, è necessario togliere l'alimentazione e ripristinarla dopo 30 sec.
After any programming changes of the dip switch of a door station or a videophone it is necessary to restart the system (power off - wait 30 seconds - power on).
28/09/2023
28/09/2023
4312-g001.dwg
Lorenzo Silla
1 1
12V ac/dc
Serratura Elettrica
Electric Lock
D0
GNDV
+V2
VID2
PTE
TRD
BUS
GND
LG LR
GND
B A
GND NO2 NC2 DMI GND
D1C2
RS-485
BUS
GND
NO
NC
C
+C
Art.4312/4312V
ID:1
CAPACITIVE DISCHARGE
12Vac/dc 2A Max
DRY CONTACTS
12Vac 1.6A Max using Art. 321
24Vac/dc 2A Max using other power supplies
D0
GNDV
+V2
VID2
PTE
TRD
BUS
GND
LG LR
GND
B A
GND NO2 NC2 DMI GND
D1C2
RS-485
BUS
GND
NO
NC
C
+C
Art.4312/4312V
ID:1
12V
230V
50/60 Hz
ART.321
230V
12V ac
Serratura Elettrica
Electric Lock
BUS
BUS
Fig. 17 Using capacitive discharge
12Vac/dc 2A Max
Videx Electronics S.p.A.
Via del Lavoro 1, 63020 Monte Giberto (FM)
Phone: +39 0734 631669 - Fax +39 0734 631669
www.videx.it - info@videx.it
Autore:
Data modifica:
Data creazione:
Title:
Notes:
Titolo:
Note: Cod.File:
Foglio
/
Dopo qualsiasi cambiamento nella programmazione dei dip switch di un posto esterno o di un videocitofono, è necessario togliere l'alimentazione e ripristinarla dopo 30 sec.
After any programming changes of the dip switch of a door station or a videophone it is necessary to restart the system (power off - wait 30 seconds - power on).
28/09/2023
28/09/2023
4312-g001.dwg
Lorenzo Silla
1 1
12V ac/dc
Serratura Elettrica
Electric Lock
D0
GNDV
+V2
VID2
PTE
TRD
BUS
GND
LG LR
GND
B A
GND NO2 NC2 DMI GND
D1C2
RS-485
BUS
GND
NO
NC
C
+C
Art.4312/4312V
ID:1
CAPACITIVE DISCHARGE
12Vac/dc 2A Max
DRY CONTACTS
12Vac 1.6A Max using Art. 321
24Vac/dc 2A Max using other power supplies
D0
GNDV
+V2
VID2
PTE
TRD
BUS
GND
LG LR
GND
B A
GND NO2 NC2 DMI GND
D1C2
RS-485
BUS
GND
NO
NC
C
+C
Art.4312/4312V
ID:1
12V
230V
50/60 Hz
ART.321
230V
12V ac
Serratura Elettrica
Electric Lock
BUS
BUS
Fig. 18 Using separate P.S.U.
12Vac 1.6A Max using Art.321
24Vac/dc 2A Max using other power supplies
Art.4312 Audio/video digital front panel