- 12 -
4000 Series
Art.4312 - Installation instructions
DEVICE
Device par. menu Parameter Name Programming method Permission Default value
1: NFC NFC By panel and PC software Only Engineer Disabled
2: Voice Chip Voice Chip By panel and PC software Only Engineer Disabled
3: Wiegand Wiegand By panel and PC software Only Engineer 26 bit
Fob width Only by PC software Only Engineer 2 byte
NFC
Enables or disables the proximity access reader within the door
panel.
Modify routine
press 1 to enter into edit mode
press 1 to enable or disable
press
to save or to exit edit mode without saving.
WIEGAND
This parameter species Wiegand protocol format. Wiegand 26
bit and 34 bit are supported.
Modify routine
press 3 to enter into edit mode
press 3 to switch from 34 bit or 26 bit and vice versa
press
to save or to exit edit mode without saving.
VOICE CHIP
Voice annunciation facility. It can be either DISABLED, SINGLE
or COMBINED.
In SINGLE mode number called is pronounced singularly (i.e.
123 ... one, two three).
In COMBINED mode number called is pronounced all in one
(i.e. 123 ... one hundred and twenty three).
Modify routine
press 2 to enter into edit mode
press 2 to switch between DISABLED, SINGLE or COMBINED
press
to save or to exit edit mode without saving.
FOB WIDTH
This option species how much of the fobs internal code is used.
It can be set to 2, 3 or four bytes.
This parameters can only e set using the PC software. When set
to 2 bytes it will send the 2 least signicant bytes of the fob,
when set to 3 will be the 3 least signicant bytes and 4 will be
the four least signicant bytes.
RESET AND TEST
AUDIO SETTINGS
From the home page or after the apartment answers a call placed from the door panel, hold pressed together 2 and 8. The door
panel will go to the audio settings page
use 1 and 3 to move the microphone volume, 4 and 6 for the speaker, 7 and 9 for the balancing
press ENTER to save the settings
hold pressed the CLEAR to exit the procedure.
RESTORE TO FACTORY PRESET
Power o then power on the panel
when the display shows VX4312, press and keep pressed the
and buttons
the display will show RESET TO FACTORY SETTING.
TESTING CONNECTION
Insert Master code;
press 5 and enter in System menu;
press 1 and start the test. Now display will look like Fig. 16.
the central line describes the current test status; Flat, Ph. Id and Bl. Id specify which in-
tercom is under test. Panel makes a call to every item stored in memory: if it receives the
acknowledge from intercom status will be OK and after 2 seconds skips to test the next
intercom. If no ack is received then status reports Fail: it is kept for 10 seconds. After that
time routine continues on testing next intercom. User can stop routine by pressing :
test is paused. A further press of will end the routine. To resume test press
stop
Testing...
Flat: 1
Ph. Id. 1
System-Test Connection
Fig. 16
Art.4312 Audio/video digital front panel