66252090 - V1.2 - 15/03/24
- 15 -
4000 Series
Art.4312 - Installation instructions
Art.4312 Audio/video digital front panel
TECHNICAL SPECIFICATIONS
Camera resolution: 976 x 496 pixel, PAL - 700TV line
Memory capacity: 3200 users
16000 codes
16000 keys
Power consumption: Stand-by: 220mA
During operation 160mA
Working voltage: Supplied by the BUS line
Working temperature: -20 +60 °C
CLEANING OF THE PLATE
Use a clean and soft cloth. Use moderate warm water or non-ag-
gressive cleansers.
Do not use:
• abrasive liquids
• chlorine-based liquids
• metal cleaning products
• antioxidant products
4312
4312R
4312V
VR4312V
4312V/NFP
4312V/F
4312RV
VR4312RV
4312RV/NFP
4312RV/F
LOWER MOBILE CONNECTION TERMINAL SIGNALS
Wiegand
D0 Data 0 output
LG Green accept LED status input
LR Red denied LED status input
GND Ground
B
RS-485 serial interface
A
GND Ground
Not used
NO2
Door open relay normally open con-
tact 2
Max 60Vdc
or 40Vac
2A
C2 Door open relay common contact 2
NC2
Door open relay normally closed
contact 2
Max 12-24
Vac/dc 2A
DMI Door monitoring input ( not used)
GND Ground
D1 Data 1 output
RS-485Relay 2
Mounting with 4000 Series front support or surface unit
MANUAL REFERENCE
To install the panel with a 4000 Series front support Art.4852 or surface unit Art.4882, please refer to the 4000 Series
Mounting instructions provided with the front support or the surface unit or download it from this link:
http://www.videx-electronics.com/download/66848500.pdf
NOTES:
• This kind of installation is only available for these versions of
the panel:
Art.4312
Art.4312R
Art.4312V
Art.4312RV
• In order to proceed with the panel installation with Art.4852
or Art.4882, remove the cross bar
A
from the support frame
as shown in Fig. 19.
• Fit the module xing brackets using the xing screws as
shown in Fig. 20.
1 2
ON