FACTORY DEFAULT PROCEDURE FOR VIDEOPHONES SUPPLIED WITH VIDEOKITS
The following procedure can be used to reset and pair the videophone and entrance panel supplied in a one apartment or two
apartment kit. Once paired the door panel will call the videophones without any further setup required. Additional setup is optional
to set device names, specic IP addresses etc. The default IP addresses are:
Entrance panel 192.168.1.180 // Videophone 1 192.168.1.181 // Videophone 2 192.168.1.182
ART.6296 VIDEOPHONE RESET FOR ONE OR TWO APARTMENT VIDEO KIT
The videophone is required to be open for this procedure
1. Power down the videophone;
2. Restore the power keeping pressed the
and buttons (Fig. 65) until the and LEDs start ashing together (Fig. 66)*;
3. To setup which videophone is the rst and which is second, press and keep pressed one of the following buttons until only the
relevant LED remains ON:
• The
button for the rst monitor of a one way or two way video kit (Fig. 67);
• The
button for the second monitor of a two way video kit (Fig. 68);
4. When the button is released, the monitor emits one long beep (videophone one) or two long beeps (videophone two) then
reboots with the new settings.
* if the monitor is connected to the cloud , the
LED ashes twice then the videophone will reboot without changing the settings, In this case, the IP wizard must be used to make any changes
to the videophone settings.