Page 18 GB 8.1 Right reserved to make technical changes!
Parameter Description Unit Range
Changed
values
Recommended
Normal
cooling
Deep-
freezer
P83 Current bus address
P84 Running time, defrosting break hours
P85 Running time, defrosting break minutes
P86 Calibration of room sensor K -20..+20
P87 Calibration of evaporator sensor K -20..+20
P88 Calibration of condenser sensor K -20..+20
Regulator parameters (access if P01 = factory-password)
P90 Room sensor -50° adjustment
P91 Room sensor, conductivity
P92 Evaporator sensor -50° adjustment
P93 Evaporator sensor, conductivity
P94 Condenser sensor -50° adjustment
P95 Condenser sensor, conductivity
P96 Switch-on delay after door contact switch is closed minutes [0..20] 0 0
P101 Temperature setting +50
P102 Status byte 1
P103 Status byte 2
P104 Status byte 3
P105 Sensor byte 7
P106 Selected unit number (for remote control)
P107 Number of devices on the bus