19
5840 711 - 01
Vitoconnect OPTO2 Installation and Operating
Specification
Specification
Vitoconnect
Rated voltage 12VDC
Wi-Fi frequency 2,4 GHz
Wi-Fi encryption Unencrypted or WPA2
Frequency band 2400.0 to 2483.5 MHz
Max. transmitting power 0.1 W (e.i.r.p.)
Internet protocol IPv4
IP assignment DHCP
Rated current 0.5A
Power consumption 5.5 W
Permissible ambient temperature
Operation
Storage and transport
41 to 104°F (+5 to +40°C)
Installation in living spaces or boiler rooms (standard ambient conditions)
-4 to 140°F (20 to +60°C)
Wall power supply
Rated voltage 100 to 240VAC
Rated frequency 50/60 Hz
Output voltage 12VDC
Output current 1A
Permissible ambient temperature
Operation
Storage and transport
41 to 104°F (+5 to +40°C)
Installation in living spaces or boiler rooms (standard ambient conditions)
-4 to 140°F (20 to +60°C)