43
Vitodens 200-W, 222-F and 242-F
Rated heating
output
kW 13 19 26 35 45 60 80 100
System size
60/100
m 10 10 10 10
System size
80/125
m 13 13 13 11 10 6
System size
100/150
m 13 9 15 15
Note
For alternative system sizes, a bal-
anced flue adaptor is required.
The following components are taken
into consideration for the maximum flue
lengths:
2 balanced flue bends 87°
Subtract other bends, tees and straight
lengths from the maximum length using
the following values:
Balanced flue bend 45°: 0.5 m
Balanced flue bend 87°: 1 m
Balanced flue inspection tee: 0.5 m
Vertical outlet for pitched or flat roofs
(cont.)