Setting and test va-
lues
Set value Initial
start-up
Service
Date:
By:
Static pressure mbar max. 57.5 mbar
Supply pressure
(flow pressure)
= for natural gas E mbar 17.4-25 mbar
= for natural gas LL mbar 17.4-25 mbar
= for LPG mbar 42.5-57.5 mbar
Tick gas type
Carbon dioxide con-
tent CO
2
&
at lower rated output % vol.
&
at upper rated output % vol.
Oxygen content O
2
&
at lower rated output % vol.
&
at upper rated output % vol.
Carbon monoxide
content CO
&
at lower rated output ppm
&
at upper rated output ppm
Ionisation current µA min. 4 µA
Commissioning/service reports