EasyManua.ls Logo

Viessmann VITOPEND 200 - Setting the Maximum Output

Viessmann VITOPEND 200
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Note
The value to be entered is approximately equivalent to the percentage of the
max. rated output, incl. DHW heating: 100 % corresponds to 29 kW output.
1. Start the boiler.
2. K + F press simultaneously:
"81" flashes (equals 24
kW output) and "A" is
displayed.
On weather-compen-
sated control units, the
display additionally
shows "Max. output".
a/b for the required output
("34" equals 10.5 kW out-
put).
d to confirm.
3. Record the setting for the maxi-
mum output on the additional type
plate supplied with the "technical
documentation". Affix the type
plate next to the type plate on top
of the boiler.
Checking the balanced flue system for soundness (annular
gap check)
A Combustion air test port (ventila-
tion air)
Further details regarding the individual steps (cont.)
29
Commissioning, inspection, maintenance
5862 831 GB
Service

Table of Contents

Other manuals for Viessmann VITOPEND 200

Related product manuals