Rated voltage 230 V~
Rated frequency 50 Hz
Rated current 6 A
Protection class I
Protection IP X 4 D to
EN 60529
Permissible ambient temperature
&
during operation 0 to +40 °C
&
during storage
and transport -20 to +65 °C
Electronic temperature limiter setting
&
during heating
operation
84 °C
&
for DHW heating 85 °C
Temperature limiter
setting 100 °C (fixed)
Line fuse (mains) max. 16 A–
Power consumption
incl. circulation
pump max. 130 W
Gas fired boilers, type C
12X , C32X , C42X , C62X , C82X category II 2ELL3P
Rated out-
put
kW 10.5 11 12 15 18 21 24 29
Rated ther-
mal load
kW 12.1 12.5 13.7 17.0 20.2 23.5 26.7 32.3
Connection
values rela-
tive to the
max. load
Natural
gas E
m
3
/h 1.27 1.33 1.44 1.78 2.12 2.46 2.80 3.39
l/min
21 22 24 29 35 41 47 56
Natural
gas LL
m
3
/h 1.49 1.54 1.68 2.10 2.48 2.98 3.28 3.97
l/min 25 26 28 35 41 48 55 66
LPG kg/h 0.95 0.97 1.06 1.31 1.56 1.82 2.07 2.25
Product ID _-0085BP0201
Lower calorific value
Lower calorific value H
uB Natural gas
E
Natural gas
LL
LPG P
kWh/m
3
9.45 8.13 24.44
MJ/m
3
34.02 29.25 88.00
Note
The supply values are only for documentation purposes (e.g. in the gas contract
application) or to estimate the supplementary volumetric settings. Because of
factory settings, the gas pressure must not be altered from these settings.