3. Prepare the electrical connections.
&
Power supply cable: NYM-
J 3 x 1.5 mm
2
, fuse max. 16 A,
230 V~, 50 Hz.
&
Accessory cables: NYM with the
required number of conductors
for the external connections.
&
Allow all cables in area "G" to
protrude 1200 mm from the wall.
Preparing for installation (cont.)
8
Preparing for installation
5592 817 GB

Table of Contents

Other manuals for Viessmann VITOPEND 200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann VITOPEND 200 and is the answer not in the manual?

Viessmann VITOPEND 200 Specifications

General IconGeneral
Fuel TypeNatural gas
Max. Heat Output24 kW
EfficiencyUp to 98%
Control SystemVitotronic
Water PressureMax. 3 bar
TypeWall-mounted condensing boiler