27
3. If applicable, use / to select the required heating/
cooling circuit
4. "Operating program"
5. Select the required operating program, e.g. "Heat-
ing and DHW"
For further possible operating programs: see page 19.
Time program
Further information can be found in chapter
"Terminology" in the appendix.
Setting the time program for central heating/central cooling
Factory setting: one time phase from 00:00 to 24:00 h
for every day of the week with the "Standard" operat-
ing status.
Note
■
The factory setting is suitable for operation with
underfloor heating systems.
■
No time program can be set for a separate cooling
circuit.
1. Extended menu:
2. "Heating" or "Heating/cooling"
3. If applicable, use / to select the required heating/
cooling circuit
4. "Time program heating" or "Time proghtg/cool-
ing"
5. Set the required time phases and operating status.
To see how to set a time program: see page 21.
Note
■
Between the time phases, rooms are neither heated
nor cooled. Only the heat pump frost protection is
active ("Standby" operating status).
■
When making settings, please bear in mind that your
heating system requires some time to heat or cool
the rooms to the required temperature.
Operating status for central heating/central cooling
"Standard"
■
Central heating/central cooling takes place with the
standard room temperature "Set room tempera-
ture": see page 26.
"Reduced"
■
Central heating takes place with the reduced room
temperature "Set red. room temp": see page 26.
Note
In the "Reduced" operating status, a heating/cooling
circuit is not cooled.
"Fixd value"
■
Central heating takes place with the max. permissi-
ble flow temperature of the respective heating circuit,
irrespective of the outside temperature.
■
Central cooling takes place with the min. flow tem-
perature of the respective heating circuit, irrespective
of the outside temperature.
■
Factory settings: your contractor may have adjusted
these values.
–
Max. heating flow temperature: 40 °C
–
Min. cooling flow temperature: 10 °C
Heating system with heating water buffer cylinder
Further information can be found in chapter
"Terminology" in the appendix.
Setting the time program for the heating water buffer cylinder
Factory setting: one time phase from 00:00 to 24:00 h
for every day of the week with the "Standard" operat-
ing status
Central heating/central cooling
Operating program (cont.)
5790940