28
The time phases for charging the heating water buf-
fer cylinder must cover all time phases for central
heating (for all heating circuits).
If you switch off heating of the heating water buffer
cylinder with the time program (all time phases are
deleted "- - : - -"), your rooms will not be heated.
We recommend that the heating water buffer cylinder
is heated continually.
1. Extended menu:
2. "System"
3. "Time prog buffer cyl"
4. Set the required time phases and operating status.
To see how to set a time program: see page 21.
Note
The heating water buffer cylinder is not heated
between the time phases. Only frost protection for
the heating water buffer cylinder is active.
When setting the time program, please bear in mind
that your heat pump requires some time to heat the
heating water buffer cylinder to the required temper-
ature.
Operating status for heating the heating water buf-
fer cylinder
"Standard"
The top section of the heating water buffer cylinder is
heated to the highest set flow temperature for all
connected heating circuits.
The set flow temperature of a heating circuit results
from the heating curve, the outside temperature and
the required room temperature.
"Reduced"
The entire volume in the heating water buffer cylin-
der is heated to the highest set flow temperature for
all connected heating circuits.
The set flow temperature of a heating circuit results
from the heating curve, the outside temperature and
the required room temperature.
"Fixd value"
The entire volume in the heating water buffer cylin-
der is heated to a fixed temperature.
Factory setting: 50 °C
Your contractor may have adjusted this value.
You can utilise the "Fixd value" operating status,
e.g. to heat up the heating water buffer cylinder with
economical night tariff power.
Note
Above a certain outside temperature, the heating water
buffer cylinder will no longer be heated in the "Fixd
value" operating status. Your contractor can adjust
this shutdown limit.
Heating curve/cooling curve
Further information can be found in chapter
"Terminology" in the appendix.
Setting curves for central heating/central cooling
Factory settings
"Slope" "Level"
Heating curve 0.6 0
Cooling curve 1.2 0
1. Extended menu:
2. "Heating" or "Heating/cooling"
3. If applicable, use / to select the required heating/
cooling circuit
4. "Heating curve" or "Cooling curve"
5. "Slope" or "Level"
Central heating/central cooling
Heating system with heating water buffer… (cont.)
5790940