29
5601 189 v1.1
Vitodens 100-W, WB1B Technical Data
Two Pipe System
Venting
Two
pipe system (room air independent) vertically vented
Vent system
diameter (in)
2* 3 4
Maximum
equivalent
length ft. (m)
86
(20)
164
(50)
200
(61)
Tw
o pipe system (room air independent) horizontally vented
Two pipe system (room air independent) hybrid
*stainless steel is not available in 2”
Combustion air: CPVC, PVC, ABS and
stainless steel (field supplied)
Flue gas: CPVC and stainless steel
(field supplied)
PP(s): (Viessmann supplied)
Vent system
diameter (in)
2* 3 4
Maximum
equivalent
length ft. (m)
86 (20) 164 (50) 200 (61)
Combustion air:
CPVC, PVC, ABS and stainless steel
(field supplied)
Flue gas: CPVC and stainless steel (field supplied)
PP(s): (Viessmann supplied)
Vent system
diameter (in)
2* 3 4
Maximum
equivalent
length ft. (m)
86 (20) 164 (50) 200 (61)
Combustion air:
CPVC, PVC, ABS and stainless steel
(field supplied)
Flue gas: CPVC and stainless steel (field supplied)
PP(s): (Viessmann supplied)
*stainless steel is not available in 2”
*stainless steel is not available in 2”
Flue
Intake
Intake
Flue
Intake
Flue