71
ViewSonic Corporation Confidential - Do Not Copy PJ503D-1
If the space is not enough, the following placements are accepted too.
Issue 2: required lamp cooling time for hot-restrike
1. The required lamp cooling time is 110 seconds in original firmware.
2. The required lamp cooling time is 480 seconds, if the power is pulled directly (fan all stop in after
cooling stage).
3. The minimum required lamp cooling time is 90 seconds, if 3 fans speed up to full speed in after
cooling stage.
Notice: Not enough cooling time will lead to 2 circumstances that are hot-restrike fail and lamp
damage.
Area A
Area B
Area A
Area B
10cm