EasyManua.ls Logo

Viking Access Systems I-770 - Radio Receiver (Typical)

Viking Access Systems I-770
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIKING TECHNICAL SUPPORT 1.800.908.0884
28
CONTROL BOARD SETUP
Viking Heater
The operator has an integrated heater. Activate this feature when the operator is used in
application temperatures down to -2F (-29°C).
! Disabled when “Solar Mode” is ON.
HEATER
CLS ON
To set the heater to turn on at the Close Limit:
1.
Use the “Diagnose” button to scroll through the LCD
Display to “HEATER CLS”
2.
Press and hold the “Stop” button on the control board.
3.
Press and release the “Diagnose” button to turn this
feature ON and OFF.
NOTE: If the application requires the gate to be held open for any reason, set the
HEATER ON for both limit positions.
HEATER
OPN ON
To set the heater to turn on at the Open Limit:
1.
Use the “Diagnose” button to scroll through the LCD
Display to “HEATER OPN
2.
Perform steps 2-3 as described above.

Related product manuals