Service Procedures
©2012 Viking Preferred Service 27
Refrigerator temperature offset is a
predetermined value, based upon model of
refrigerator. This value can be set in Mode
B as a separate adjustment or can be set
automatically in Mode B when selecting
model code, where several control values
are set by eeprom. Table 1 on Page 35 lists
eeprom values set by model code.
If you are not already in Mode A, go back to
Mode A instructions on Page 24.
Once you are in Mode A (PrA in display),
press and release "ACTIVATE
CONTROLS" one time and display
will change to "Prb", signifying that
control is now in Program Mode B,
see illustration below.
ACTIVATE
CONTROLS
FRZ
TEMP
LOWER
Refrigerator Offset
Model Value
5301 -6
5361 -5
HIGHER
This value should be set to
appropriate value in table below.
ACTIVATE
CONTROLS
To exit Mode A and retain any changes
made in system up to this point
you must press and hold
"ACTIVATE CONTROLS" for
three seconds until you hear
three audible beeps. This signies
that the changes were written to the
eeprom and that the system has
left Mode A and returned to normal
operation. Failure to do this will cause
system to time out after 10 minutes
and any changes will be lost.
Exiting Mode A
Program Mode B
Adjust Refrigerator Temperature Offset
Press and release "REF TEMP"
pad once, the "REFRIGERATOR"
indicator will illuminate and the
current freezer offset will be
displayed along with
o
F.
Using "HIGHER and LOWER" pads adjust
value as in illustration below.