Service Procedures
©2012 Viking Preferred Service 31
HIGHER
HIGHER
LOWER
LOWER
MAX
REF
MAX
REF
Adjust Refrigerator Upper Temperature
Limit
While in Mode C, press and hold
"MAX REF" and and then hold the
"HIGHER" pad for three seconds,
this will result in the display
changing to "rUL".
Pressing and releasing "HIGHER
and LOWER" pads will increase
or decrease the set point, which
should be set at 47
o
F.
Adjust Refrigerator Lower Temperature
Limit
While in Mode C, press and hold
"MAX REF" and and then hold the
"LOWER" pad for three seconds,
this will result in the display
changing to "rLL".
HIGHER
LOWER
Pressing and releasing "HIGHER
and LOWER" pads will increase
or decrease the set point, which
should be set at 33
o
F.
Defrost lockout adder
This adjustment is not a eld adjustment and
should not be performed by technicians. This
is a factory only adjustment.
If you see "dLA" in the display, immediately
exit Mode C by holding "ACTIVATE
CONTROLS" for three seconds until you get
three audible beeps. Return to your previous
actions.
Defrost start delay
This adjustment is not a eld adjustment and
should not be performed by technicians. This
is a factory only adjustment.
If you see "dSd" in the display, immediately
exit Mode C by holding "ACTIVATE
CONTROLS" for three seconds until you get
three audible beeps. Return to your previous
actions.
Defrost termination delay
This adjustment is not a eld adjustment and
should not be performed by technicians. This
is a factory only adjustment.
If you see "dtd" in the display, immediately
exit Mode C by holding "ACTIVATE
CONTROLS" for three seconds until you get
three audible beeps. Return to your previous
actions.