13
SW24.W
EN
OUT
RAU
Auxiliary Radio Output Conguration
Default
1
Impulsive: the output is active for 1 s following the RAU command from the remote control
Timed: the output is active for the time set in the RAUT parameter following the RAU command from
the remote control
Bistable: the output works in Step-Step ON/OFF mode
RAUT
RAU output timing
Default
1
1 1 s (minimum time)
600 600 s (maximum time)
LCO
Courtesy light timer
Default
120
1 1 s (minimum time)
300 300 s (maximum time)
SCA
SCA output operating mode
Default
1
1
Gate closed: o
Gate open: on xed
2
Gate closed: o
Gate moving: intermittent
Gate open: on xed
Indeterminate position: intermittent pause of 1 s every 5
3
Gate closed: o
Gate opening slow intermittent
Gate open on xed
Gate closing intermittent
Indeterminate position: intermittent pause of 1s every 5
4
Gate stopped on xed
Gate moving o
5
Gate closed o
Gate moving on xed