14
SW24.W
EN
IN
Input conguration
C(X)
C1/C2/C3/C4 command input
1
Step-step (PP)
The step-step control:
- with the gate stopped and closed, opens the gate
- in opening, stops or closes the gate according to the step-step logic setting (L10)
- with the gate stopped after opening, closes the gate
- in closing, stops or opens the gate according to the step-step logic setting (L10)
- with the gate stopped after closing, opens the gate
Default C1
2
Pedestrian (PED)
Opens the gate to the pedestrian position
It acts like a step-step if the command is given with the gate beyond the pedes-
trian position
Default C2
3
Open (OPEN)
The open command:
- with the gate stopped and closed, opens the gate
- in opening is ignored
- with the gate open, resets the pause time
- with the gate stopped, opens the gate
- in closing, opens the gate
Default C3
4
Close (CLS)
The close command:
- with the gate stopped and closed, is ignored
- in opening, closes the gate
- with the gate stopped, closes the gate
- in closing is ignored
Default C4
5
Timer (TIM)
The timer command:
- when closed, opens the gate and keeps it open as long as the contact remains
closed
- when the contact is released it closes the gate
6
Pedestrian Timer (TIMP)
Has the same function as the timer command but on the pedestrian position