15
SW24.W
EN
IN S(X)
S1/S2/S3/S4 safety input
OFF O
Default
S3/S4
1
Photocell closing (PHC)
The closing photocell:
- with the gate stopped, allows the gate to open
- in opening does not intervene
- with the gate open, does not allow it to close and when released will reset the
pause time
- in closing, reopens the gate immediately
Default
S1
2
Photocell (PH)
The photocell:
- with the gate stopped, does not allow the gate to open
- during opening, stops the movement and when released proceeds to open the
gate-with the gate open, it does not allow it to close and when released it resets
the pause time
- in closing stops the movement and when released reopens the gate
Default
S2
3
Opening photocell (PHO)
The opening photocell:
- with the gate stopped, allows the gate to open
- in opening, recloses it completely
- with the gate open, allows it to close and does not reset the pause time
- in closing does not intervene
4
Sensitive edge with NC clean contact (BAR)
- with the gate stopped, does not allow the gate to open
- in opening disengages
- with the gate open, does not allow it to close and when released will reset the
pause time
- in closing disengages
5
8.2 KΩ balanced sensitive edge (8K2)
Same behaviour as the NC sensitive edge
6
Stop (STP)
- stops the gate
Interrupts the automatic closing as per the logic stop setting from stop (L12)
7
Photocell closing checked (PHC)
As per closing photocell but with check
8
Photocell checked (PHT)
As per photocell but with check
9
Photocell opening checked (PHC)
As per opening photocell but with check
10
NC sensitive edge checked (BART)
As per KΩ NC sensitive edge but with check
11
8.2 KΩ balanced sensitive edge checked (8K2T)
As per 8.2 KΩ sensitive edge but with check