Control panel logic settings
L1
Automatic closing
Default
ON
OFF Automatic closing o󰀨
ON Automatic closing on
L2
Pause time
Default
30
1 1 s (minimum time)
180 180 s (maximum time)
L3
Pedestrian pause time
Default
20
1 1 s (minimum time)
180 180 s (maximum time)
L4
State on power up
Default
OP
CL
Gate in closed position:
The rst step-step command opens the gate.
OP
Gate in open position:
The rst step-step command closes the gate. If automatic closing is on, after the pause time
the gate closes
L5
Apartment block
Default
OFF
OFF Apartment block function o󰀨
1 Ignores closing and stop commands in opening
2 Ignores closing and stop commands in opening and in pause
3 Ignores closing and stop commands in opening, in pause and in closing
L6
Rapid closing
Default
OFF
OFF Rapid closing function o󰀨
1
Rapid closing in gate mode:
The control panel starts to count the clearance time (L7) from when the closing photocell is
released, when the clearance time expires it closes again.
2
Rapid closing in barrier mode:
The control panel starts to count the clearance time (L7) from when the closing photocell is
released, when the clearance time expires it closes again. If the closing photocell is occupied
again, it does not command it to reopen but to stop. When released again it continues with
closing. The closing photocell returns to normal operating after complete closure
L7
Clearance time (adjustable at intervals of 1 s)
Time after which the gate closes again if the rapid closing (L6) is on
Default
2
1 Minimum clearance time
10 Maximum clearance time
L8
Pre-ash
Flashing time of the ashing light before the gate starts to move
Default
OFF
OFF Pre-ash disabled
3 3 s pre-ash
4 4 s pre-ash
5 5 s pre-ash
L9
Manned
Default
OFF
OFF Manned function o󰀨
1
Step-step command disabled, remote controls not working. The control panel accepts only
open and close commands
2
Emergency manned. In normal standard operating conditions, with the safety devices oc-
cupied it works as manned.