18) CHECKING THE POSITION OF THE FINAL LIMIT
SWITCH CAM AND PLATES
Before final testing of the lift, check that the limit stop
(Fig. 58/a-59/a) is correctly positioned.
This position is correct if the dimensions are as shown
in the drawings in Fig. 58 and 59.
19) STRETCHING THE CHAIN
Stretch the chain (Fig. 60/b) by undoing the nuts (Fig. 60/
e) and screwing down the hexagon (Fig. 60/ a).
Take care not to apply excessive tension, as this will
mean too much strain on the drive shafts (Fig. 60/c
and Fig. 60/d). Tighten the nuts (Fig. 60/e) firmly
when done.
20) FINAL TESTING
Power up the lift and perform the following func
-
tional tests:
- Load capacity test:
- Load the lift with 1.1 times the rated working load
stated against “working load” on the dataplate.
- Send the lift up and down several times, checking its
stability on the rail.
- Final testing for lifts with sections of rail having
gradient of less than 20°:
- Move the lift to the area with gradient of more than
25° and check that the cam tripping roller is 0.5÷1.5
mm from the cam (see Fig. 62).
- If the roller has to be moved towards or away from
the cam, remove the bracket (Fig. 65/a) and turn the
clutch wheel hub (Fig. 65/b) using the spanner pro-
vided (Fig. 65/c). After adjustment (30 daN/m) fit the
bracket (Fig. 65/a) and fix the two screws (Fig. 65/d)
with 243.
- Then move the lift to the area with gradient of less than
20°, and place a weight of 250 kg on it with its centre
of gravity 150 mm from the edge (see Fig. 61).
- Check that the lift does not tilt by more than 2°.
- Preliminary Checks
- Perform the checks described in section 6.1 (Page 8)
of the User Manual.
- Testing the safety gear
- Test the safety gear as described in Section 10.1 point
“d” of the User Manual. (This test must be performed
with no load on the lift).
- Checking the interlocking of the platform with
independent or retractable arms (manual plat
-
form)
- Check that as long as the descent side arm is in the
rest position the platform remains locked, whether in
the working or the rest position.
FIG.58
FIG.59
FIG.60
HIGH
LEVEL
LOW
LEVEL
37
a
40
a
a
c
b
d
e e
40

Other manuals for vimec V65 B.R.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the vimec V65 B.R. and is the answer not in the manual?

vimec V65 B.R. Specifications

General IconGeneral
Brandvimec
ModelV65 B.R.
CategoryStairlifts
LanguageEnglish

Related product manuals