- 39 -
Dwell Time the dwell time if Call By Event is set to Motion, Alarm, or Both.
Press +/- buttons to adjust the value (3-60 seconds, discrete).
Audio – the AUDIO IN corresponding to this camera. The audio data for the
selected AUDIO IN will be recorded with the video data for this camera. Press
+/- buttons to select none (N/A) or AUDIO Inputs (1, 2). The default setting is
“N/A”.
Record Quality – the record quality for this camera. Press +/- buttons to select
the value (1-9, with 1 the lowest (rough) quality, 9 the highest (fine) quality).
Event Record IPS – the IPS (Images Per Second) for this camera if certain event
(Motion, Alarm) occurs for this camera. This camera will be recorded at this
rate for Post-record time since the event occurs. (Please refer to the following
sections for Post-record time.) Press +/- buttons to select the value (0 – 25 (PAL)
/ 30 (NTSC), discrete).
Pre-record IPS – the pre-record IPS for this camera if certain event (Video Loss,
Motion, Alarm) occurs for this camera. This camera is recorded at this rate for
Pre-record time before the event occurs. (Please refer to the following sections
for Pre-record time.) For this DVR, the value is always the same as Event
Record IPS. Please note that the total Event Record IPS / Pre-record IPS
should not exceed the system recording capacity (NTSC: 240/CIF, 120/Half-D1,
60/Full-D1; PAL: 200/CIF, 100/Half-D1, 50/Full-D1), or the system will lower
the actual rate automatically at recording.
Normal Record IPS the normal record IPS for this camera. This camera will
be recorded at this rate if no event occurs. Press +/- buttons to select the value
(0 – Pre-record IPS for this camera, discrete).