Manual VIPA System 300V Chapter 3 Profibus DP
HB130E - IM - Rev. 08/26 3-19
The identifier-related diagnostic tells whether modules of the System 300V
DP slaves are defective or not.
The length of the identifier-related diagnostic data is fixed at 5 Byte.
Identifier-related diagnostic
Byte Bit 7 ... Bit 0
6 Bit 5 ... 0: Length identifier-related diagnostic data
000101: Length 5 Byte (fix)
Bit 7 ... 6: Code for identifier-related diagnostic
01: Code 01 (fix)
7 Bit 0: Module at plug-in location 1
Bit 1: Module at plug-in location 2
Bit 2: Module at plug-in location 3
Bit 3: Module at plug-in location 4
Bit 4: Module at plug-in location 5
Bit 5: Module at plug-in location 6
Bit 6: Module at plug-in location 7
Bit 7: Module at plug-in location 8
8 Bit 0: Module at plug-in location 9
Bit 1: Module at plug-in location 10
.
.
.
Bit 7: Module at plug-in location 16
9 Bit 0: Module at plug-in location 17
Bit 1: Module at plug-in location 18
.
.
.
Bit 7: Module at plug-in location 24
10 Bit 0: Module at plug-in location 25
Bit 1: Module at plug-in location 26
.
.
.
Bit 7: Module at plug-in location 32
The Bits in Byte 7 and 10 are set when:
• the according module is dismantled.
• a not projected module is plugged-in.
• a plugged-in module denies access.
• the according module announces a diagnostic interrupt.
Identifier-related
diagnostic
IM 353-1DP00