Table of Zones
Zone # (led flashes) Zone Name
1 Trunk/Sensor 2
2 Shock Sensor
3 Door
5 Ignition
Note: The Warn-away trigger does not report on the LED.
Nuisance Prevention Circuitry (NPC)
NPC monitors all alarm zones and, if any are triggered excessively,
bypasses them until corrected. If a point of entry (trunk, hood, door)
is left open following a forced entry, it is bypassed. It becomes active
again only after being closed.
Bypassed sensors automatically reset after one hour, and after the
vehicle is driven. Disarming then re-arming the alarm does not reset
bypassed sensors.