© 2005 directed electronics, inc.
33
features description
bitwriter
®
B-1 FORCED PASSIVE ARMING ON/OFF: These settings control whether the system
arms passively in the event a door is left open accidentally by the user. Passive
arming must be programmed on for this feature to work.
• Forced passive arming ON (Default): in this setting if passive arming is pro-
grammed on and a zone is active (door open) after the ignition is turned off, the
system will bypass the zone after 1 hour, then arm and monitor the rest of the
security zones.
• Forced passive arming OFF: in this setting the system will not passive arm if
any zone is left open after the ignition is turned off.
B-2 NUISANCE PREVENTION CIRCUITRY™ (NPC™) ON/OFF: These settings con-
trol the number of times a sensor can trigger the system within a given time peri-
od.
• NPC ON (Default): in this setting any sensor that triggers more than 3 times
within a 1 hour period will be bypassed for a minimum of 1 hour. If within that
1 hour the system sees the same sensor trigger again it will not activate the siren
and will restart the 1 hour timer.
• NPC OFF: in this setting the sensors will trigger repeatedly until the system is
disarmed.
B-3 DEALER SECURITY FEATURES ON/OFF. This feature is not available on this
model.
B-4 TRANSMITTER PROGRAMMING UNLOCKED/LOCKED: This feature is not
available on this model.
B-5 FEATURE PROGRAMMING UNLOCKED/LOCKED:
• Unlocked (default): In this setting the features can be changed using the Valet
switch and the vehicle OEM transmitter.
• Locked: in this setting the features can not be changed using the Valet switch
and the vehicle OEM Transmitter. If locked, the unit will emit 1 long chirp when
trying to enter feature programming.
B-6 SIREN DURATION The Bitwriter can adjust the siren duration setting anywhere
from 1 second to 180 seconds in length.