INSTRUCTION FOR USE ENGLISH
12
BASIC TROUBLESHOOTING
Trouble Probable causes Remedy
work
Not plugged in to power source Plug into a grounded outlet
Faulty power cable Contact Distributor
Faulty extension power cable
Replace with new extension power cable
Building circuit breaker tripped
Solution
working
Vacuum / pump switch not on Turn on switch
Vacuum / pump switch faulty Contact Distributor
Faulty solenoid Contact Distributor
Faulty solution pump Contact Distributor
Pump overheated
Determine cause and allow 30 minutes for
Loose or broken wiring Contact Distributor
Vacuum mo-
tor not work-
ing
Vacuum / pump switch not on Turn on switch
Vacuum / pump switch faulty
Vacuum motor thermal overload tripped Check for obstruction and allow 30 minutes to
Faulty vacuum motor Contact Distributor
Worn carbon brushes Contact Distributor
Poor pick up
Air leaking around recovery gasket
Ensure recovery lid is firmly tightened
Vacuum gasket damaged or worn Replace gasket
Loose vacuum hose connections
Ensure vacuum hose connections are tight
Defective vacuum hose Replace vacuum hose
Loose vacuum hose cuffs
Ensure cuffs are secure to the housing
Remove obstruction from vacuum hose
Uneven or no
solution spray
Solution tank is empty or low
Vacuum / pump switch not on
Dirty or plugged spray tips
Clean or replace spray tips
Improper spray tip size or spray angle
Clogged solution tank filter
Pinched or kinked solution hose
Check for obstructions and kinks and reroute or