VIQUA Arros™ Models:
Arros 9-IHS10, Arros 9-IHS12,
Arros 15-IHS10, Arros 15-IHS12,
Arros 15-IHS22, Arros 22-IHS22
Owners Manual
520520-R_RevB
Question and Answer IconNeed help?

Do you have a question about the Viqua Arros 9-IHS10 and is the answer not in the manual?

Overview

The VIQUA Arros™ is an ultraviolet (UV) water system designed to provide advanced UV technology for water treatment, ensuring years of trouble-free operation with minimal maintenance. It is available in several models, including Arros 9-IHS10, Arros 9-IHS12, Arros 15-IHS10, Arros 15-IHS12, Arros 15-IHS22, and Arros 22-IHS22. These systems have been validated through microbial testing for UV dose delivery to inactivate Cryptosporidium, Giardia, Escherichia coli (E. coli), and Fecal Coliform.

Function Description:

The VIQUA Arros™ system utilizes UV light to disinfect water, effectively inactivating harmful microorganisms without the use of chemicals. Water flows through a UV Chamber where it is exposed to UV-C light emitted by a UV Lamp Unit. This process ensures that the water is safe for consumption. The system is designed for permanent connection to water lines and is intended for potable water applications. It is not to be used in or above water, outdoors, or in swimming pools.

Important Technical Specifications:

  • UV Lamp Unit: Hard glass coated UV lamp with a long consistent life of approximately 9000 hours, sealed within a GE 214 fused quartz sleeve.
  • Controller: 100-240VAC/50/60Hz.
  • Power Cords: Available in models 260251-R and 260252-R, depending on the specific Arros model.
  • Filters: Includes sediment filters (CMB-510-HF, CMB-520-HF) and carbon filters (C2-02PB) for pre-treatment, which are crucial for optimal UV performance.
  • Water Quality Parameters (Recommended for Installation):
    • Iron: < 0.3 ppm (0.3 mg/L)
    • Hardness: < 7 gpg (120 mg/L) (If > 7 gpg, water should be softened)
    • Turbidity: < 1 NTU
    • Manganese: < 0.05 ppm (0.05 mg/L)
    • Tannins: < 0.1 ppm (0.1 mg/L)
    • UV Transmittance: > 75% (contact factory for recommendations if UVT < 75%)
  • Flow Rates (based on End of Lamp Life; 20°C; 95% UVT):
    • Arros 9-IHS10/IHS12:
      • US Public Health 16mJ/cm²: 17 gpm (64.3 lpm)
      • VIQUA Standard 30mJ/cm²: 9 gpm (34.1 lpm)
      • NSF/EPA 40mJ/cm²: 7 gpm (26.5 lpm)
    • Arros 15-IHS10/IHS12/IHS22:
      • US Public Health 16mJ/cm²: 29 gpm (109.8 lpm)
      • VIQUA Standard 30mJ/cm²: 15 gpm (56.8 lpm)
      • NSF/EPA 40mJ/cm²: 12 gpm (45.4 lpm)
    • Arros 22-IHS22:
      • US Public Health 16mJ/cm²: 42 gpm (159 lpm)
      • VIQUA Standard 30mJ/cm²: 22 gpm (83.3 lpm)
      • NSF/EPA 40mJ/cm²: 16 gpm (60.6 lpm)
  • Dimensions:
    • UV Chamber:
      • Arros 9 models: 28.4 cm x 10.16 cm (11.2" x 4.0")
      • Arros 15 models: 42.0 cm x 10.16 cm (16.5" x 4.0")
      • Arros 22 models: 57.2 cm x 10.16 cm (22.52" x 4.0")
    • Controller: 26.67 cm x 12.7 cm x 16.51 cm (10.5" x 5.0" x 6.5")
    • Overall (L x H x D):
      • Arros 9-IHS10: 43.0 cm x 44.5 cm x 22.9 cm (16.95" x 17.5" x 9.0")
      • Arros 9-IHS12: 63.4 cm x 69.9 cm x 22.9 cm (24.95" x 27.5" x 9.0")
      • Arros 15-IHS10: 43.0 cm x 52.9 cm x 22.9 cm (16.95" x 20.82" x 9.0")
      • Arros 15-IHS12/IHS22: 63.4 cm x 69.9 cm x 22.9 cm (24.95" x 27.5" x 9.0")
      • Arros 22-IHS22: 63.4 cm x 69.9 cm x 22.9 cm (24.95" x 27.5" x 9.0")
  • Inlet/Outlet Port Size: 3/4" FNPT / 3/4" MNPT.
  • Shipping Weight: Ranges from 40lbs (18.1kg) to 50lbs (22.7kg) depending on the model.
  • Electrical: Max. Current 1.5 Amp. Power consumption ranges from 35 W to 65 W. Lamp Watts range from 24 W to 52 W.
  • Maximum Operating Pressure: 100 psi (6.9bar).
  • Ambient Water Temperature: 2-40 °C (36-104 °F).
  • Lamp Type: High Output.
  • Display: LCD Touch Screen.
  • UV Chamber Material: 304 SS.

Usage Features:

  • User Interface: The system features an LCD touch screen display for easy navigation and monitoring.
  • Startup Sequence: Guides the user through initial setup, including language selection (English, French, Spanish) and model selection.
  • Warranty Registration: Recommended online registration via QR code or website.
  • Home Screen: Displays remaining lamp life (counts down from 365 to 0 days) and Lamp Status (ON/OFF).
  • Alarms:
    • Minor Warning Alarm: Initiated when lamp life reaches 30 days remaining, and again at 14 days. The lamp head top cap (Halo) illuminates amber.
    • Major Lamp Alarm: Initiated when lamp life reaches 0 days or in case of UV Lamp Unit failure. The lamp head top cap (Halo) illuminates red. This indicates that treatment may be compromised and servicing is required.
  • Menu Screen: Provides access to:
    • Spare Parts Menu: Helps identify replacement part numbers.
    • Settings Menu: Allows adjustment of system model number, display and Halo brightness, orientation, user language, screen saver time, and a reset option to return to default settings.
    • Information Menu: Displays system information such as firmware version, model number, and serial number.
    • Contact Dealer Information: Provides resources to find a local dealer.
  • Lamp Head Status Lights (Halo):
    • Blue: Normal operation (no faults, lamp on).
    • Amber: Minor alarm condition (lamp life < 30 days).
    • Red: Major alarm condition (lamp life = 0 days or UV Lamp Unit failure).
  • Firmware Updates: The system's Wi-Fi capability allows for firmware updates via the VIQUA app on a smartphone or tablet. This feature is for updates only and does not provide system status or control.

Maintenance Features:

  • Annual UV Lamp Unit Replacement: To ensure ongoing optimal operation, the UV Lamp Unit must be replaced annually (after approximately 9000 hours of continuous operation). Only genuine VIQUA replacement lamps should be used to avoid damage to the control module, safety risks, and voiding the warranty.
  • Cleaning Procedure:
    • Distribution System Sanitization: The entire distribution system located after the UV System must be chemically cleaned to ensure it is free from contaminants. This should be done immediately after installation and repeated whenever the UV System is shut down for service, without power, or inoperative. The procedure involves shutting off water, removing cartridges, pouring household bleach into filter housings, allowing it to sit, then flushing all water outlets until bleach is no longer smelled.
    • Quartz Envelope Cleaning: Minerals in the water can form a coating on the quartz envelope, reducing UV light transmission. The quartz envelope should be cleaned with a cloth soaked in CLR, vinegar, or a mild acid, then rinsed with water. If the envelope cannot be cleaned, the UV Lamp Unit assembly must be replaced.
  • Cartridge Replacement: Filter cartridges should be changed regularly, approximately 3-4 times per year, depending on water quality and usage. A gradual drop in water pressure indicates that pre-filter cartridges are nearing the end of their useful life. The procedure involves disconnecting power, shutting off water, releasing pressure, removing old cartridges, installing new ones, and then restoring water flow and power.
  • Troubleshooting Guide: The manual provides a comprehensive troubleshooting section to address common issues such as no power, GFCI trips, leaks, alarms, bacterial contamination, pressure drop, high bacteria counts, heated product water, milky water, and unit leaking. It offers possible causes and solutions for each symptom.
  • Seasonal Home/Freezing Temperatures: Always drain the UV Chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures to prevent damage.
  • Bypass Assembly: The use of a bypass assembly is recommended for "off-line" maintenance. If water is used during bypass conditions, a supplementary disinfectant is required, and a "DO NOT CONSUME THE WATER" tag should be physically installed. Water consumed during bypass must be boiled for twenty minutes.
  • Ground Fault Circuit Interrupter (GFCI) Protection: The electronic controller must be connected to a GFCI receptacle, and the green ground wire ring terminal must be securely fastened to the ground stud on the UV Chamber.
  • System Protection: A UL1449 certified (or equivalent) transient voltage surge suppressor is strongly recommended to protect the controller.

The VIQUA Arros™ system is designed for ease of installation and maintenance, but adherence to the instructions and recommended water quality parameters is crucial for optimal performance and to maintain warranty coverage. The UV Lamp Unit contains mercury, and proper disposal is required if the lamp breaks.

Viqua Arros 9-IHS10 Specifications

General IconGeneral
BrandViqua
ModelArros 9-IHS10
CategoryWater Filtration Systems
LanguageEnglish