Display, Keys and Menus
Setup Menus
VT200/220 Technical Manual, Rev 1.00.01 34 Doc # TM-VT200/220-EN
Par Description Values
2.8 Operator print type change (Fn 20-
30).
0=NO 1=YES
2.d Data bits/Parity serial channel 1 N8 = 8 Data bits/no parity, 07 = 7 Data bits/odd
parity, E7 = 7 Data bits/even parity,
2.11 1 line with date, time and indicated
weight
07-10-03 15:25:20 00500kgG
0=NO 1=YES
2.b Baud rate serial channel 1.
12= 1200 bps
24= 2400 bps
48 = 4800 bps
96 = 9600 bps
Above 2.2, 2.b and 2.d settings only suitable to set 2.t=0.2 for Continuous
Weight Output.
SETUP > SETUP 3 (Com 2 Settings)
Par. Description Values
3.t Instrument communication type. 00=disabled; 01 =continuous weight output;
02=EDP protocol output; 03=printer protocol output;
06=continuous weight w/tare output; 11=continuous
output with dual scale; 65-89=master/slave protocol
address
3.1 Timeout control. 0=NO 1=YES
3.2 Handshake. 0=NO 1=YES
3.3 Operator disable. 0=NO 1=YES
3.4 Host enquiry. 0=NO 1=YES
3.5 Remote keyboard commands. 0=NO 1=YES
3.6 Continuous weight output format LEO or AND
3.7 (Reserved for future use)
3.8 Debug. 0=NO 1=YES
3.b Baud rate serial number 2. 24 = 2400 bps
96 = 9600 bps
19 = 19200 bps
38 = 38400 bps
57 = 57600 bps