5. PROGRAMMING
D-304762 PowerMaster-10/30 G2 Installer's Guide
61
Message Description
Cable unplugged The Ethernet cable is not connected to the Broadband Module.
Check lan config This message appears in any of the following cases:
• Incorrect Broadband Module IP has been entered.
• Incorrect subnet mask has been entered.
• Incorrect default gateway has been entered.
• DHCP server failure.
Rcvr#1 UnReach.
Rcvr#2 UnReach.
Receiver 1 or 2 is inaccessible, as follows:
• Wrong receiver IP has been entered.
• Receiver failure.
• WAN Network failure.
Rcvr#1 UnReg.
Rcvr#2 UnReg.
The PowerMaster unit is not registered to IP receiver 1 or 2.
Timeout err. Broadband Module does not respond to test result within 70 sec.
Invalid result Broadband Module responds with a result code that is not recognized by the PowerMaster.
5.10 User Settings
This USER SETTINGS menu provides you with a gateway to the user settings through the regular user menus.
Refer to the PowerMaster User's Guide for detailed procedures.
Caution! If after having programmed the user codes the system does not recognize your installer code, this
indicates you must have programmed a user code that is identical with your installer code. If so, access the user
menu and change the code that is identical with your installer code. This will re-validate your installer code
5.11 Factory Default
The FACTORY DEFLT menu enables you to reset the PowerMaster parameters to the factory default parameters. To
obtain the relevant parameters defaults, contact the PowerMaster dealer. Reset factory default parameters as follows:
Step 1 Step 2 Step 3 Step 4
Step 5
Select "09:FACTORY DEFLT"
menu
Select "<OK> to restore" Enter Installer Code Resetting of factory default
parameters is underway
PLEASE WAIT…
to Step 1
Notes:
1) For PowerMaster with 2 installer codes, INSTALLER code and MASTER INSTALLER code, only the master installer
code enables to perform the factory default function.
2) If the Soak Test
1
is active, performing factory default will restart the Soak Test.
5.12 Serial Number
The SERIAL NUMBER menu enables reading the system serial number and similar data for support purposes only. To
read the system serial number and other relevant data proceed as follows:
Step 1
Step 3
Select "10:SERIAL
NUMBER" menu
[1]
Click next repeatedly to view
relevant data.
to Step 1
Definition
0907030000.
Control panel serial number
JS702275 K16.010
Control panel software version
JS700421 v1.0.01
2
Control panel LCD software
version
PANEL ID 100005
Control panel ID for
PowerManage connectivity
1
Soak Test is not applicable for UL installations
2
Refers to PowerMaster-30 G2 only