7. Preparaon before use
7.1 Safety guidelines
Don’t plug the VITO machine when you get it immediately for the rst me wait unl VITO can acclimate
BEFORE START WORKING WITH VITO YOU MUST TURN OFF THE FRYER.
Clean VITO before using it the rst me. (See chapter 10 Care and servicing)
Make sure that the local voltage is conform to the voltage on the type label (13)of VITO!
DO NOT MOVE VITO WHILE FILTRATION IS IN PROGRESS!
Do NOT get the power cord in contact with hot oil / shortening! (8)
The maximum operang temperature is 175°C/350°F! (oil temperature)
Do NOT run the pump-lter unit (9) outside the fryer!
Pay aenon to heang elements, grids or thermal sensors in the fryer!
To li or transport VITO only pick it up using the black handles (7)!
7.2 Storage of VITO
The handles of the drip pan (4) can be fastened oponally at the short or the long side.
Place VITO always into the drip pan (4), aer use or for transport
Store VITO only in the drip pan (4)
Allowed ambient / storage temperature: +10 to +35°C (50° to 95°F)
7.3 Filtraon duraon
The factory sengs for one ltraon cycle of VITO is:
VITO 30: 4,5 min, max. 3 cycles
VITO 50: 4,5 min, max. 12 cycles
VITO 80: 4,5 min, max. 12 cycles
Upon reaching the maximum number of cycles, VITO must cool down before used for the next ltraon.
Cool down phases
up to 2 hours:
VITO 30
VITO 50 and VITO 80 (if power cord (8) is pulled out)
approximately 15 min
VITO 50 and VITO 80 (if power cord (8) is plugged in)
If the temperature of VITO is too high, the overheat protecon will acvate.
(VITO 80 has addional acousc beep signal)
Power Indicator (red LED) (1) “Power” is ashing.
The ltraon process will stop.
7.4 Checking the factory sengs
Pressing the push buon (3) will be conrmed by one ash of the Power indicator (red LED) (1)
1. Press and hold the push buon (3)
2. Plug VITO in.
3. Hold the start/stop buon (3) for 5 seconds. (VITO 80 will beep)
4. Programmed cycle me is displayed by ashing of the indicators
5. The red LED (1) indicates 1 minute per ash
The green LED (2) indicates 30 seconds per ash
e.g. 4x red = 4 min
1x green = 30 seconds
= duraon of lter cycle: 4min 30sec.
7.5 Programming the cycle me
To re-program the cycle me, start with the steps in 7.4 checking the factory sengs, then:
1. Press push buon (3) instantly aer cycle length was displayed
2. Press push buon (3) to increase the cycle me by 30 sec. (Re-program starts at 0 sec!)
(e.g. press 3x for 1,5min etc.)
3. Once the designated cycle me is set, wait for the green LED (2) to ash once ( VITO 80 beeps).
4. Pull out the power cord (8).
The new cycle me is now saved.
7.6 Acvate/deacvate the beep and set sound level (VITO 80 only)
To set the sound level of the beep, start with the steps in 7.4 checking the factory sengs, then: