7.33 IR cut control
Group: ircutcontrol (capability.nvideoinprofile > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
mode auto,
day,
night,
di,
schedule
auto 6/6 Set IR cut control mode
daymodebegintime 00:00~23:59 07:00 6/6 Day mode begin time
daymodeendtime 00:00~23:59 18:00 6/6 Day mod end time
bwmode <boolean> 1 6/6 Switch to B/W in night mode
if enabled
7.34 UART control
Group: uart (capability.nuart > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40] <product
dependent>
1/4 Name of the PTZ driver.
ptzdrivers_i<0~19,
127>_location
string[128] < product
dependent >
1/4 Full path of the PTZ driver.
enablehttptunnel <boolean> 0 4/4 Enable HTTP tunnel channel
to control UART.
Group: uart_i<0~(n-1)> n is uart port count (capability.nuart > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
baudrate 110,300,600,12
00,2400,3600,4
800,7200,9600,
19200,38400,57
600,115200
9600 4/4 Set baud rate of COM port.