trigger boot,
di,
motion,
seq,
recnotify,
tampering,
vi,
volalarm,
pir
(capability.npir
>0)
boot 6/6 Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“motion” = Video motion detection
“seq” = Periodic condition
“recnotify” = Recording notification.
“tampering” = Tamper detection.
“vi”= Virtual input (Manual trigger)
"volalarm" = Audio detection
"pir" = Passive infrared sensor trigger
(capability.npir>0)
triggerstatus String[40] trigger 6/6 The status for event trigger.
exttriggerstatus String[40] <blank> 6/6 The status for event trigger.
exttriggerstatus1 String[40] <blank> 6/6 The status for event trigger.
exttriggerstatus2 String[40] <blank> 6/6 The status for event trigger.
exttriggerstatus3 String[40] <blank> 6/6 The status for event trigger.
di 0~3 1 6/6 Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input. The
LSB indicates DI 0.
mdwin 0~7 0 6/6 Indicate the source window id of motion
detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
mdwin0 0~7 0 6/6 Similar to mdwin. The parameter takes
effect when profile 1 of motion detection
is enabled.
vi 0~7 0 6/6 Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
One bit represents one digital input. The
LSB indicates VI 0.