224 - User's Manual
steps 1 ~ <motor_max> Motor’s moving steps.
It works only if function=zoom | focus and direction=forward |
backward.
<motor_max> is refer to remote_focus_focus_motor_max or
remote_focus_zoom_motor_max which replied from
"function=getstatus"
iris N/A Open iris or not.
It works only if function=auto | scan.
Export Files
Note: This request requires Administrator privileges.
Method: GET
Syntax:
For daylight saving time configuration file:
http://<servername>/cgi-bin/admin/exportDst.cgi
For language file:
http://<servername>/cgi-bin/admin/export_language.cgi?currentlanguage=<value>
PARAMETER VALUE DESCRIPTION
currentlanguage 0~20 Available language lists.
Please refer to:
system_info_language_i0 ~ system_info_language_i19
.
For setting backup file:
http://<servername>/cgi-bin/admin/export_backup.cgi?backup
Upload Files
Note: This request requires Administrator privileges.
Method: POST
Syntax:
For daylight saving time configuration file:
http://<servername>/cgi-bin/admin/upload_dst.cgi
Post data: