7.13 Exposure window setting per channel
Group: exposure_c<0~(n-1)> for n channel products
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
mode auto, custom auto 4/4 The mode indicates how to
decide the exposure.
auto: Use full view as the only
one exposure window.
custom: Use customized
exposure window.
win_i0_enable <boolean> 0 4/4 Enable or disable the window.
win_i0_home <coordinate> (150,110) 4/4 Left-top corner coordinate of
the window.
win_i0_size <window size> (100x75) 4/4 Width and height of the
window.
Group: exposure_c<0~(n-1)>_profile for m profile and n channel product
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
i<0~(m-1)>_mode auto, custom auto 4/4 The mode indicates how
to decide the exposure.
auto: Use full view as the
only one exposure
window.
custom: Use customized
exposure window.
i<0~(m-1)>_win_i0_enable <boolean> 0 4/4 Enable or disable the
window.
i<0~(m-1)>_win_i0_home <coordinate> (150,110) 4/4 Left-top corner
coordinate of the
window.
i<0~(m-1)>_win_i0_size <window size> (100x75) 4/4 Width and height of the
window.