Vixel 9000 Series Installation & Configuration Guide APPENDIX C Troubleshooting
62
Link Recovery N_Port link recovery RxLinkResets
TxLinkResets
RxOls
TxOls
incoming corrupted data RxMissingDelims
loop LIPs Loop LIPs (Loop Initialization
Primitives) are not shown in the
Port Link Statistics; to verify that
a Loop LIP recovery condition is
occurring, review the Event Log
for the following messages:
Link Failure, indicating a
physical connection change,
such as a cable disconnection or
device power off.
Link Down, indicating that the
attached device is issuing LIPs
to the switch.
User Restarted Port, indicating
that either a Management
request or a Stealth LIP
propagation was passed to this
port.
physical link problems SyncLoss
SignalLoss
RxClkLoss
Issue Probable cause(s)
Look for an increase in
these Link Statistic(s)