Temperature Ranges
Review the table below for an overview of operational temperature ranges
for your Volta System.
F° (C°) Range Description
-4°F to 140°F
(-20°C to 60°C)
Safe Storage
Range
The Energy Storage Pack may be
stored within this range. At certain
temperatures within this range,
Volta System functionality may be
prevented.
37.4°F to 116.6°F
(3°C to 47°C)
Charging Range Within this temperature range, the
Volta System accepts charge and
has full functionality.
-4°F to 134.6°F
(-20°C to 57°C)
Discharging
Range
Within this temperature range, the
Volta System turns on and powers
devices. Refer to the Charging
Range (within this table) to identify
the range within the Discharging
Range at which the Volta System
does not charge.
-4°F to 59°F
(-20°C to 15°C)
Heating Control
On Range -
Shore Power
If equipped with internal heating
pads, the Volta System’s heating
control is on to actively warm the
Energy Storage Pack when con-
nected to AC power (shore power)
and within this temperature range.
-4°F to 42.8°F
(-20°C to 6°C)
Heating Control
On Range
If equipped with internal heating
pads, the Volta System’s heating
control is on to actively warm the
Energy Storage Pack when within
this temperature range.
The values listed in this table represent approximate values that may