51
Resistance
Range Resolution Accuracy
200.0 Ω 0.1 Ω
± (1.0 % + 2)
2.000 kΩ 0.001 kΩ
20.00 kΩ 0.01 kΩ
200.0 kΩ 0.1 kΩ
2.000 MΩ 0.001 MΩ
± (1.2 % + 3)
20.00 MΩ 0.01 MΩ
Overload protection: 600 V
Capacitance
Range Resolution Accuracy
2.000 nF 0.001 nF ± (4 % + 10)
20.00 nF 0.01 nF
± (4 % + 5)
200.0 nF 0.1 nF
2.000 µF 0.001 µF
20.00 µF 0.01 µF
200.0 µF 0.1 µF
2.000 mF 0.001 mF ± 10 %
20.00 mF 0.01 mF ± 10 %
Overload protection: 600 V
Diode test
Test voltage: approx. 3.2 V
Resolution: 1 mV
Overload protection: 600 V
Acoustic continuity tester
Resolution: 0.1 Ω
<10 Ω continuous tone
Overload protection: 600 V
NCV non-contact AC voltage test
Test voltage: ≥100 - 600 V/AC
Gap: max. 15 mm