EasyManua.ls Logo

Volvo Penta D4 - Page 111

Volvo Penta D4
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reason: Communication fault in any of;
Battery Control Modul (BCU)
Interceptor Module (ICM)
Power Control Module (PCU)
Swim Platform Interface (SPIF)
Action: Contact a Volvo Penta workshop if the fault remains.
Check corrosion status
Reason: Communication fault between Power Control Module PCU and Corrosion Protection Module (CPM).
Action: Contact a Volvo Penta workshop.
Check Engine
Reason: Communication fault in EMS.
Action: Contact a Volvo Penta workshop.
Check EVC System
Reason: Fault in PCU or Thruster system.
Water in bellow or in cover.
Action: Check S-Link cables and connectors.
Contact a Volvo Penta workshop if the fault remains.
Communication fault
Reason: Communication fault within any of the following:
Helm station
Powertrain Control Unit (PCU)
Water Sport I/O node.
Symptom: Engine performance might be affected.
Action: Contact a Volvo Penta workshop as soon as possible.
Check Multilink
Reason: Communication fault to multisensor.
Action: Contact a Volvo Penta workshop.
Check Thruster
Reason: Thruster system failure.
Action: See Thruster Manual or contact Thruster supplier service center.
Check Shift Actuator
Reason: Transmission failure.
Gear actuator failure.
Transmission oil pressure low.
Symptom: Engine emergency stopped.
Action: Contact a Volvo Penta workshop.
Check Transmission
Reason: Propeller stuck
Symptom: Gear automatically set to neutral and engine speed reduced.
Action: Regain propulsion by moving lever to neutral.
Fault Code Register
47712786 11-2022 © AB VOLVO PENTA 107

Table of Contents

Other manuals for Volvo Penta D4

Related product manuals