40
Instruments
Fuel alarm un-acknowledged Pop up
The fuel level alarm un-acknowledged pop-up will ap-
pear and flash if the fuel level alarm is enabled and
enabled active state is transmitted from the EVC-
unit. The display buzzer will also sound as for stan-
dard EVC alarms. All standard EVC-system alarms
as well as depth alarm will have priority over the fuel
level alarm. Pressing any key will instigate a fuel level
alarm acknowledge.
The display shows the actual fuel tank alarm level in
the window as a percentage of fuel remaining. If both
port & starboard alarms are active in a dual engine
system, then the alarm with the lowest fuel level is
displayed in the pop-up.
Fuel level signal lost
If the fuel level alarm is enabled and the fuel level
signal is lost, for instance in the case of sensor mal-
function, the fuel level alarm signal loss pop-up will
appear and flash at a slow rate.
Fuel alarm acknowledged Pop up
The fuel level alarm acknowledged pop-up will appear
constantly if the fuel level alarm is enabled. This will
show the percentage of fuel remaining value until the
enabled inactive message is received from the EVC-
unit.