Operating instructions
Stopping the engine 43
Long-term parking
IMPORTANT! If the machine is not going to be used every
day, all cylinders should be greased as protection against
corrosion.
1 Wash the machine down and touch up any damaged paint fi-
nish to avoid rusting.
2 Treat unprotected parts with an anti-corrosion agent. Lubricate
the machine thoroughly and grease bright surfaces (lifting/tip-
ping cylinders etc.).
3 Fill the fuel tank and the hydraulic oil tank to the max. marks.
4 Cover the exhaust pipe (for outdoors parking).
5 Make sure the coolant level in the cooling system is high
enough (in case of frost).
6 Park the machine on level and firm ground. Locations with a
high risk of earth slides or flooding and the danger of freezing
to the ground should be avoided. Do not park the machine on
slopes.
Check after long-term parking
Q All oil and fluid levels
Q Tension of all belts
Q Air cleaner unit
Q Track tension