IR610 high performance vector control frequency inverter user manual Chapter 5 function code table
- 54 -
Functio
n code
Parameter name
Description
Default
makes the speed droop a long with load increase.
When the motor outputs rated torque, actual frequency drop is equal to P1.41. User can adjust this
parameter from small to big gradually during commissioning.
P01.43
Textile frequency setting
0: relative to center of textile frequency
1: relative to maximum frequency
0
P01.44
Textile frequency
0.0%100% relative to center of textile
frequency
P01.43 = 0Textile frequency Aw = P01.44 *
center frequency
P01.43 = 1: Textile frequency Aw = P01.44 *
max frequency
0.0%
P01.45
Jump frequency
0.0%50.0% relative to textile frequency
0.0%
P01.46
Textile period
0.1s3000.0s
10.0s
P01.47
Triangle wave rising time
coeffcient
0.1%100.0% relative to textile period
50.0%