«Cleaning mode»
This mode triggers the cleaning of the thermostatically controlled mirror.
Cleaning the mirror involves heating of the mirrors surface to a set temperature (Parameter
Т(°С) – i.d.R. +55°C).
In this mode the display shows the following information: (illus. 7):
current temperature of the CP 2M’s mirror Т;
current signal value for water Uw;
current signal value for hydrocarbons Uhc;
current housing temperature of the CP 2M B.
Illustration 7:
Cleaning mode menu
Select the respective sub-menu point using the «◄» button.
To exit the cleaning mode, touch the «►» button.
Finally, select the «measure: W» to determine the dpW value or the «measure: HC» mode
to determine the dpHC value.
«Service Menu»
The «Service Menu» provides the operator with access to the CP 2M’s service functions. A
password is required in order to access this (illus. 8 -10).
Illustration 8:
Password entry
The factory default service menu password code is «11111».