18 Technical data
100_0102_td_0005.fm 46
The following points must be observed:
Only use permitted extension cables.
Refer to nameplate for details of type designation and voltage of this machine.
Refer to the following table for the required cross-section area.
Machine type Voltage
[V]
Extension
[m] (ft)
Cross-section area of
cable
[mm
2
]
AR52/6/042 42 3~ <
11 (36.1) 2,5
<
18 (59.5) 4
<
25 (82.0) 6
AR52/6/250 250 3~ <
150 (492.1) 1,5
AR52/9/042 42 3~ <
15 (49.2) 2,5
<
23 (75.5) 4
<
34 (111.5) 6
AR53/3/400 400 3~ <
150 (492.1) 1,5
AR53/6/042 42 3~ <
11 (36.1) 2,5
<
18 (59.5) 4
<
25 (82.0) 6
AR53/6/250 250 3~ <
150 (492.1) 1,5
AR53/9/042 42 3~ <
15 (49.2) 2,5
<
23 (75.5) 4
<
34 (111.5) 6
AR53/9/250 250 3~ <
150 (492.1) 1,5
AR54/6/250 250 3~ <
150 (492.1) 1,5