21 Technical data
100_0102_td_0009.fm 56
21 Technical data
21.1 ARFU26
Designation Unit ARFU26/6/230 ARFU26/6/115 UK ARFU26/6/120 US
Item no. 5100004243 5100004245 5100004244
Rated current A 6,00 12,00 12,00
Rated voltage V 220 - 240 110 - 130 110 - 130
Rated frequency Hz 50 - 60 50 - 60 50 - 60
Rated output kW 1,10 1,10 1,10
Phases ~ 1 1 1
Centrifugal force kN 2,30 2,30 2,30
Vibrations rpm 6.000 6.000 6.000
Hz 100 100 100
Centrifugal force max. kN 3,47 3,47 3,47
Length mm (in) 223 (8.8) 223 (8.8) 223 (8.8)
Width mm (in) 190 (7.5) 190 (7.5) 190 (7.5)
Height mm (in) 102 (4.0) 102 (4.0) 102 (4.0)
Weight kg (lb) 12,40 (27.34) 12,40 (27.34) 12,40 (27.34)
Length of power cable m (ft) 15 (49.2) 15 (49.2) 15 (49.2)
Cross section mm
2
(in
2
) 1,5 (0.05) 1,5 (0.05) 1,5 (0.05)
Plug CEE 7/7, Typ EF CEE 2P+E 16A
110V 4H
NEMA 5-15P - 14W
47
Power cable H 07 RN-F 3G1,5 H 07 RN-F 3G1,5 H 07 RN-F 3G1,5
Motor type Induction motor
ON/OFF switch
Operation display
Class rating l l l
Protection class * IP67 IP67 IP67
Storage temperature range °C (°F) -20 – +60
(-4 – +140)
-20 – +60
(-4 – +140)
-20 – +60
(-4 – +140)
Operating temperature
range
°C (°F) -10 – +40
(14 – +104)
-10 – +40
(14 – +104)
-10 – +40
(14 – +104)
Housing external
temperature
°C (°F) 80 (176) 80 (176) 80 (176)
Sound pressure level L
pA
**
dB(A) < 70 < 70 < 70
Standard
EN ISO 11201, EN 12649
*
Only guaranteed with a Wacker Neuson power cable.
**
Measured at distance of 1 m (3.2 ft).