21 Technical data
57 100_0102_td_0009.fm
21.1.1 Extension cable
The following points must be observed:
Only use permitted extension cables.
Refer to nameplate for details of type designation and voltage of this machine.
Refer to the following table for the required cross-section area.
WARNING
Warning about voltage.
Serious injuries from electric shock.
Check power cable and extension cable for signs of damage.
Only use extension cables for which grounded conductors are connected to the plug
and the coupling (only for machines of protection class I + III, see chapter "Technical
data").
Machine type Voltage
[V]
Extension
[m] (ft)
Cross-section area of
cable
[mm
2
]
ARFU26/6/230 220 - 240 1~ <
50 1,2
<
83 2,5
ARFU26/6/115 UK
ARFU26/6/120 US
110 - 130 1~ <
12 1,5
<
21 2,5
Machine type Voltage
[V]
Extension
[m] (ft)
Cross-section area of
cable
[AWG]
ARFU26/6/230 220 - 240 1~ <
44 16
<
69 14
ARFU26/6/115 UK 110 - 130 1~ <
11 16
<
17 14
<
27 12