Maintenance
T01032GB.fm 33
5. Maintenance
5.1 Maintenance schedule
Parts Maintenance jobs Maintenance interval
Air filter
Check for external damage and tight fit. Check filter
cartridge, clean or replace if necessary.
daily
Fuel tank Check tank lid for tight fit, replace if necessary.
Drive engine Check oil level, top up if necessary.
Exciter Check for tightness.
Drive engine First oil change. 20 hours
Centre pole
Grease moveable locking device, and spindle for
pole height adjustment.
monthly
Drive engine
Clean spark plug, check spark plug gap 0,7 mm.
Centre pole head Check oil level, top up if necessary.
V-belt Check V-belt tension - retension, if need be.
Protective frame
Check fastening screws of protective frame and
central suspension for tight fit.
Drive engine Oil change.
100 hoursExhaust muffler Remove combustion residue from spark arrester.
Exciter
Oil change.
Check oil level-fill up, if need be. 150 hours
Oil change. 250 hours
Drive engine
Valve clearance - Check, set - 0,15 mm intake
valve, 0,20 mm exhaust valve.
300 hours