9 Operation and use
100_0202_op_0009.fm 27
1. Bring the decompression lever into the middle position.
2. Turn the engine using the starting crank in the counterclockwise direction so long till it starts turning
evidently easily (10 - 20 crank rotations).
3. Press the lever for mechanical oil pressure monitoring for 15 seconds.
4. Fill the metering device with engine oil up to the upper edge.
5. Place the cover and press it firmly.
6. Pull the decompression lever upwards till it stops.
7. Then, start the engine immediately, refer to the chapter – Operating the machine (manual start).
Item Designation Item Designation
1 Decompression lever 3 Metering device
2 Oil pressure monitoring lever
NOTE
Within the range of the metering device cover, clean the dirt and remove the cover.
NOTE
Two consecutive fills are required.