9 Operation and use
28 100_0202_op_0009.fm
9.3.3 Operating the machine (electric start)
1. Insert the ignition switch key into the ignition lock and turn towards right; the charge control lamp lights
up, the acoustic signal sounds..
2. Turn ignition switch key to position ll. As soon as the engine starts, release the ignition switch key.
3. Put throttle control in idling.
4. Let the machine warm up a few minutes in idling.
9.3.4 Operating the machine (recoil starter)
1. Turn the fuel cock to ON.
2. Put throttle control in idling.
3. Turn the ignition key switch to l.
4. Pull out the starter rope slowly up to the compression resistor.
5. Press and release the decompression lever.
6. Quickly and strongly pull the starter rope on the starter handle while pulling the rope as far as
possible.
7. Let the machine warm up a few minutes in idling.
Item Designation Item Designation
1 Throttle control 3 Ignition lock
2 Decompression lever 4 Charge control lamp
NOTE
In case of extreme cold, also actuate the decompression lever upwards. In this position,
the decompression automatic system engages audibly and the engine is ready to start.
NOTE
As soon as the engine starts, vibration starts.
CAUTION
Do not allow the starter rope to snap back against the engine. Slowly guide back by hand
to prevent damage to the starter.